Artificial lighting retrofit proposal of a public building: the case of postgraduate block on the Federal University of ABC

Authors

  • Julián Alberto Marín Universidade Federal do ABC - UFABC
  • Igor Fuser Universidade Federal do ABC - UFABC
  • Jesús Franklin Andrade Universidade Federal do ABC - UFABC

Keywords:

retrofit, artificial lighting, energy efficiency, visual comfort, measurement and verification

Abstract

One of the main challenges for human beings is the provision of energy to big cities and their buildings, as well as the correct use of the available resources. Increasing the life cycle of buildings that involve technological retrofit processes should enable cost savings, provide comfort for building users, and minimize the impact on natural resources. This research presents an artificial lighting retrofit proposal for a public building in Santo André, São Paulo. The experimental method evaluates the characterization of artificial lighting inside the building, and based on measurements and simulations, it is proposed that the 16W fluorescent lighting be replaced with 10W LED technology. The environments were simulated using Domus-Procel Edifica software and DIAlux software was used to validate the energy efficiency and visual comfort results before and after retrofit. The measurement and verification method (M & V) was used to determine the resulting energy savings. Optimal visual comfort conditions and reductions of around of 37.5% of rated power required by artificial lighting in the building were obtained. The simulation case study confirms improved building performance with respect to energy efficiency.

Downloads

Download data is not yet available.

Author Biographies

Julián Alberto Marín, Universidade Federal do ABC - UFABC

Curso de Pós-Graduação em Energia - Estudante Mestrado

Igor Fuser, Universidade Federal do ABC - UFABC

Curso de Pós-Graduação em Energia - Prof. Dr.

Jesús Franklin Andrade, Universidade Federal do ABC - UFABC

Curso de Pós-Graduação em Energia - Prof. Dr.

References

ABNT. Iluminância de interiores, NBR 5413. Associação Brasileira de Normas Técnicas. Rio de Janeiro, p. 13. 1992.

CARLO, J.; LAMBERTS, R. Parâmetros e métodos adotados no regulamento de etiquetagem da eficiência energética de edifícios - parte 1: método prescritivo. Ambiente Construído, v. 10, n. 2, p. 7-26, 04/06 2010.

CIANCIARDI, G.; BRUNA, G. C. Procedimentos de sustentabilidade ecológicos na restauração dos edifícios citadinos. Cadernos de Pós-Graduação em Arquitetura e Urbanismo, Universidade Mackenzie, São Paulo, v. 4, n. 1, p. 113-127, 2004.

CORRÊA, R. L. Sustentabilidade na construção civil. (Monografia) Escola de Engenharia UFMG. Belo Horizonte, p. 10-67. 2009.

DIETZ, T.; ROSA, E.; YORK, R. Environmentally efficient well-being: rethinking sustainability as the relationship between human well-being and environmental impacts. Human Ecology Review, v. 16, n. 1, p. 114-123, 2009.

DURANTE, L. C. et al. Sistema de iluminação integrada em edificação lat 15 sul e potencial de uso de geração fotovoltaica. Revista Hábitat Sustentable, Concepción, v. 4, n. 2, p. 04-15, Diciembre 2014.

EPE. Consumo de Energia no Brasil Análises Setoriais. Empresa de Pesquisa Energética. Rio de Janeiro, p. 14-25. 2014a. (Nota Técnica DEA 10/14.).

EVO. International Performance Measurement & Verification Protocol. Efficiency Valuation Organization. Washington, DC, USA. 2010. (1).

HADDAD, J. Possíveis avanços para a eficiência energética no Brasil e como a regulação pode contribuir para seu aprimoramento. VI Congresso brasileiro de regulação. Rio de Janeiro: [s.n.]. 2009. p. 22.

HINNELLS, M. Technologies to achieve demand reduction and microgeneration in buildings. Energy Policy, v. 36, n. 12, p. 4427–4433, dez. 2008.

HUANG, B. et al. Development of high performance solar LED lighting system. Energy Convers Management, v. 51, n. 8, p. 1669–1675, ago. 2010.

KHAN, N.; ABAS, N. Comparative study of energy saving light sources. Renewable and Sustainable Energy Reviews, v. 15, n. 1, p. 296–309, jan. 2011.

LI, D. H. W.; LAM, T. N. T.; WONG, S. L. An analysis of energy-efficient light fittings and lighting controls. Applied Energy, v. 87, n. 2, p. 558–567, fev. 2010.

LIBESKINDLLOVET ARQUITETOS. Libeskindllovet Arquitetos, 2006. Disponivel em: <http://lla.arq.br/>. Acesso em: 23 abr. 2015.

MA, Z. et al. Existing building retrofits: methodology and state of the art. Energy and Buildings, v. 55, p. 889-902, dez. 2012.

MACHADO, R. X.; SILVA, J. D. D. S.; MARQUES, N. B. A concepção de desenvolvimento sustentável. Universidade Regional UNIJUÍ. Ijuí, Rio Grande do Sul, p. 1-15. 2005.

MADEIRA, G.; NETO, D. N. Estudo de impacto de vizinhança. UFABC. Santo André, p. 170. 2014.

MARÍN-AGUDELO, J. Avaliação de uma proposta de retrofit baseada em indicadores sustentáveis utilizados nas metodologias AQUA e LEED: O caso do Bloco de pós-graduação da Universidade Federal do ABC (UFABC). Universidade Federal do ABC UFABC. Santo André - SP, p. 139. 2015.

MELBOURNE GOVERNMENT. 1200 buildings, What is a building retrofit? City of Melbourne, 2015. Disponivel em: <http://www.melbourne.vic.gov.au/1200buildings/what/Pages/WhatIsRetrofit.aspx>. Acesso em: 15 jan. 2015.

MME. Ministério de minas e energia, Brasil, 2013. Disponivel em: <http://www.mme.gov.br/mme>. Acesso em: 2 dez. 2013.

MORAES, P. R. D. B. Análise do desenvolvimento de indicadores para a avaliação de sustentabilidade de edifícios brasileiros. (Dissertação de Mestrado) Universidade Estadual de Campinas. Campinas, p. 199. 2011.

ONU. Relatorio Brundtland. Conferência Mundial sobre Meio Ambiente e Desenvolvimento Sustentável, Organização das Nações Unidas. Nueva York: [s.n.]. 1987.

ONU. World population prospects: the 2004 revision, highlights. United Nations. New York, p. 91. 2005.

ONU. Organização das Nações Unidas, 2014. Disponivel em: <http://www.un.org/>. Acesso em: 8 set. 2014.

PEREIRA, D. A. D. M. Análise e melhoramento do conforto lumínico de um bloco educacional público. VIII Congresso Nacional de Excelência el Gestão. Nitéroi: [s.n.]. 2012. p. 2-15.

PHILIPS. Phillips, 2015. Disponivel em: <http://www.ecat.lighting.philips.com.br/>. Acesso em: 25 maio 2015.

PROCEL. Centro brasileiro de informação de eficiencia energética, 2014. Disponivel em: <http://www.procelinfo.com.br>. Acesso em: 2 ago. 2014.

ROCHA, E. T. Construcciones sostenibles: materiales, certificaciones y LCA1. Revista nodo, Bogotá, v. 6, n. 11, p. 99-116, nov. 2011.

RYCKAERT, W. R. et al. Criteria for energy efficient lighting in buildings. Energy and Buildings, v. 42, n. 3, p. 341–347, mar. 2010.

UFABC. Projeto arquitetônico UFABC: Campus Santo André. Universidade Federal do ABC. Santo André, p. 210. 2006.

UFABC. Registro de consumo de energia elétrica e água da UFABC: Campus Santo André. Universidade Federal do ABC, Prefeitura Universitária. Santo André, p. 20. 2014.

UFABC. Plano de Gestão de Logística Sustentável UFABC, 2015a. Disponivel em: <http://www.ufabc.edu.br/index.php?option=com_content&view=article&id=9314>. Acesso em: 28 jul. 2015.

WU, M. et al. Economic feasibility of solar powered LED roadway lighting. Renew Energy, v. 34, n. 8, p. 1934–1938, ago. 2009.

Published

2015-12-30

How to Cite

Marín, J. A., Fuser, I., & Andrade, J. F. (2015). Artificial lighting retrofit proposal of a public building: the case of postgraduate block on the Federal University of ABC. Sustainable Habitat, 5(2), 21–31. Retrieved from https://revistas.ubiobio.cl/index.php/RHS/article/view/2128

Issue

Section

Artículos