Thermal comfort analysis of dwellings with different construction systems located above 3000 m.a.s.l. in the Rural Andean Zone of Ecuador

Authors

DOI:

https://doi.org/10.22320/07190700.2025.15.01.08

Keywords:

thermal insulation, bioclimatic architecture, energy efficiency, construction systems

Abstract

This research examines the thermal comfort of four non-air-conditioned dwellings located in a rural Andean region of Ecuador, at an altitude of 3,000 meters above sea level (masl), to identify passive design strategies. The study describes the environmental and construction characteristics of two neo-vernacular dwellings built with natural materials (TRA-01 and TRA-02) and two dwellings with modern materials (CON-01 and CON-02). Indoor and outdoor temperature and relative humidity variables were monitored for eight days, along with envelope surface temperatures. The comfort range was evaluated using the operating temperature. The results showed that three dwellings had stable indoor temperatures, although only the straw bale dwelling was partially within the comfort range. The study concludes that the envelope’s thermal insulation, bioclimatic design, and construction quality are needed to maintain adequate temperatures in these cold climate zones.

Downloads

Download data is not yet available.

Author Biographies

Andrea Nataly Moreno-Albuja, University of Cuenca, Riobamba, Ecuador

Master in Construction
Graduate-Student

Vanessa Guillén-Mena, University of the Basque Country, Bilbao, Spain

Master in Energy Efficiency and Sustainability in Building and Urban Planning
PhD Student in Energy Efficiency and Sustainability in Engineering and Architecture

Nathalie Madeleine Santamaria-Herrera, University of the Basque Country, Bilbao, Spain - National University of Chimborazo, Riobamba, Ecuador

Master in Architecture
PhD student in Energy Efficiency and Sustainability in Engineering and Architecture - Professor of the Architecture Department

References

ASHRAE Standard 55 (2020). Thermal Environmental Conditions for Human Occupancy. https://www.ashrae.org/technical-resources/bookstore/standard-55-thermal-environmental-conditions-for-human-occupancy

Atecyr (2010). Fundamentos de climatización. Atecyr, Ed.

CERRÓN CONTRERAS, A. (2022). Sistemas de calefacción pasiva para lograr el confort térmico en viviendas alto andinas de Perú. Cátedra Villarreal, 10(1), 37–48. https://doi.org/10.24039/cv20221011379 DOI: https://doi.org/10.24039/cv20221011379

CHANG, S., HE, W., YAN, H., YANG, L., y SONG, C. (2021). Influences of vernacular building spaces on human thermal comfort in China’s arid climate areas. Energy and Buildings, 244, 110978. https://doi.org/10.1016/j.enbuild.2021.110978 DOI: https://doi.org/10.1016/j.enbuild.2021.110978

COJOCARU, A., y ISOPESCU, D. (2021). Passive Strategies of Vernacular Architecture for Energy Efficiency. Bulletin of the Polytechnic Institute of Iași. Construction. Architecture Section, 67(2), 33 - 44. https://doi.org/10.2478/bipca-2021-0013 DOI: https://doi.org/10.2478/bipca-2021-0013

DHAKA, S., MATHUR, J., BRAGER, G., y HONNEKERI, A. (2015). Assessment of thermal environmental conditions and quantification of thermal adaptation in naturally ventilated buildings in composite climate of India. Building and Environment, 86, 17–28. https://doi.org/10.1016/J.BUILDENV.2014.11.024 DOI: https://doi.org/10.1016/j.buildenv.2014.11.024

GALLARDO, A., PALME, M., LOBATO-CORDERO, A., BELTRÁN, R. D., y GAONA, G. (2016). Evaluating thermal comfort in a naturally conditioned office in a temperate climate zone. Buildings, 6(3), 27. https://doi.org/10.3390/buildings6030027 DOI: https://doi.org/10.3390/buildings6030027

GUILLÉN MENA, V., QUESADA MOLINA, F., LÓPEZ CATALÁN, M., ORELLANA VALDÉS, D., y SERRANO, A. (2015). Eficiencia energética en edificaciones residenciales Energetic efficiency in residential Buildings. Estoa. Journal of the Faculty of Architecture and Urbanism, 4(7), 59-67. https://doi.org/10.18537/est.v004.n007.07 DOI: https://doi.org/10.18537/est.v004.n007.07

HARMAN, L. (2010). Confort térmico en viviendas altoandinas un enfoque integral. Balcari Editores.

INAHMI. (2023). Datos de estación meteorológica San Juan. https://servicios.inamhi.gob.ec/

INEN-ISO 7730. (2014). Norma Técnica Ecuatoriana [NTE] - Servicio Ecuatoriano de Normalización [INEN], Sobre ISO 7730: Ergonomía del entorno térmico.

INDRAGANTI, M. (2010). Behavioural adaptation and the use of environmental controls in summer for thermal comfort in apartments in India. Energy and Buildings, 42 (7), 1019–1025. https://doi.org/10.1016/J.ENBUILD.2010.01.014 DOI: https://doi.org/10.1016/j.enbuild.2010.01.014

Instituto Nacional de Estadística y Censos [INEC]. (02, abril de 2024). Censo Ecuador Resultados. https://www.censoecuador.gob.ec/resultados-censo/#historicos

Ministerio de Desarrollo Urbano y Vivienda (2018). NEC Norma Ecuatoriana de la Construcción. Eficiencia-Energética en Edificaciones Residenciales (EE) (código NEC-HS-EE). https://www.habitatyvivienda.gob.ec/wp-content/uploads/2023/03/4.-NEC-HS-Eficiencia-Energetica.pdf

Ministerio de Vivienda y Agenda Urbana (2022). Documento Básico HE- Ahorro de energía. https://www.codigotecnico.org/pdf/Documentos/HE/DBHE.pdf

MINO-RODRÍGUEZ, I. (2021). A thermal comfort model for high-altitude regions in the Ecuadorian Andes [Tesis de Doctorado, University College London]. UCL Discovery. https://discovery.ucl.ac.uk/id/eprint/10139857

MOSCOSO-GARCÍA, P., y QUESADA-MOLINA, F. (2023). Analysis of Passive Strategies in Traditional Vernacular Architecture. Buildings, 13(8), 1984. https://doi.org/10.3390/buildings13081984 DOI: https://doi.org/10.3390/buildings13081984

QUESADA MOLINA, F., y BUSTILLOS YAGUANA, D. (2018). Indoor environmental quality of urban residential buildings in Cuenca-Ecuador: Comfort standard. Buildings, 8(7), 90. https://doi.org/10.3390/buildings8070090 DOI: https://doi.org/10.3390/buildings8070090

SUASACA PELINCO, L., APAZA MAMANI, A., FLORES ALFARO, J. A., PERCA CHURA, O. A., y QUINTO MACHACA, W. (2020). Influencia de las pacas de avena en la temperatura y humedad en las viviendas en zonas altoandinas. Revista Investigación & desarrollo, 20(1), 215–227. https://doi.org/10.23881/idupbo.020.1-15i DOI: https://doi.org/10.23881/idupbo.020.1-15i

TAPIA, W. E. (2017). El confort térmico en las edificaciones de arquitectura vernácula de la ciudad de Loja y Malacatos [Tesis de Magíster, Universidad de Cuenca]. Repositorio Institucional de la Universidad de Cuenca. https://dspace-test.ucuenca.edu.ec/handle/123456789/97/simple-search?query=&sort_by=score&order=desc&rpp=10&filter_field_1=subject&filter_type_1=equals&filter_value_1=Arquitectura+tradicional&filter_field_2=subject&filter_type_2=equals&filter_value_2=Dise%C3%B1o+arquitect%C3%B3nico&etal=0&filtername=author&filterquery=Tapia+Chocho%2C+Wilson+Eduardo&filtertype=equals

TARTARINI, F., SCHIAVON, S., CHEUNG, T., y HOYT, T. (2020). CBE Thermal Comfort Tool: Online tool for thermal comfort calculations and visualizations. SoftwareX, 12, 100563. https://doi.org/10.1016/j.softx.2020.100563 DOI: https://doi.org/10.1016/j.softx.2020.100563

UNE-EN 16798-1 (2020). Asociación Normalización Española [UNE]. Eficiencia energética de los edificios. Ventilación de los edificios. Parte 1: Parámetros del ambiente interior a considerar para el diseño y la evaluación de la eficiencia energética de edificios incluyendo la calidad del aire interior, condiciones térmicas, iluminación y ruido. Módulo 1-6. Asociación Española de Normalización. https://www.une.org/encuentra-tu-norma/busca-tu-norma/norma?c=N0063261

UNE-EN-ISO 7726 (2002). Asociación Normalización Española [UNE]. Ergonomía de los ambientes térmicos- Instrumentos de medida de las magnitudes físicas. Asociación Española de Normalización. https://www.une.org/encuentra-tu-norma/busca-tu-norma/norma?c=N0026478

VILLACÍS, D. (2010). Construcciones patrimoniales de Chimborazo. En Instituto Nacional de Patrimonio Cultural (Ed.), Guía de bienes culturales del Ecuador-CHIMBORAZO (pp. 39-45). Ediecuatorial. https://www.patrimoniocultural.gob.ec/wp-content/uploads/2023/05/14_CHIMBORAZO.pdf

Published

2025-06-30

How to Cite

Moreno-Albuja, A. N., Guillén-Mena, V. ., & Santamaria-Herrera, N. M. (2025). Thermal comfort analysis of dwellings with different construction systems located above 3000 m.a.s.l. in the Rural Andean Zone of Ecuador. Sustainable Habitat, 15(1), 98–115. https://doi.org/10.22320/07190700.2025.15.01.08

Issue

Section

Artículos